PNEUMATIC FLOW METER

Categories: ,

Pneumatic Flow Meters are ideal for monitoring air compressor outputs, pneumatic tool air consumption, and industrial gas flows. The rugged and reliable design includes all metal pressure vessels, allowing safe installation in industrial systems and industries. Enjoy the unrestricted mounting capabilities and easy installation with multiple ports available.

  • Choice of Materials: Select from aluminum, brass or stainless steel to meet system and media compatibility requirements.
  • Unrestricted Mounting: Allows for horizontal, vertical or inverted installation. Superior Exterior Design Weather-tight for use outdoors and/or on systems where wash downs are required.
  • Rugged and Reliable: These monitors are constructed with all metal pressure vessels, allowing safe, permanent installation in industrial systems.
  • Multiple Ports Available: Standard selection of NPT, SAE and BSPP ports reduces the amount of adapters required for installation

PNEUMATIC FLOW METER

Basic Variable Area Flow Meter is ideal for monitoring pump performance as well as measuring fluids in hydraulic circuits and cooling systems.

Pneumatic Flow Meters are ideal for monitoring air compressor outputs, pneumatic tool air consumption, and industrial gas flows. The rugged and reliable design includes all metal pressure vessels, allowing safe installation in industrial systems and industries. Enjoy the unrestricted mounting capabilities and easy installation with multiple ports available.

Technical Sheets

Instruction Manual
Catalog Page

Specifications

Measuring Accuracy: ±2.5% of full scale in the center third of the measuring range; ±4% in upper and lower thirds
Repeatability: ±1% of full scale
Flow Measuring Range: 2-1300 SCFM @ 100 PSIG (1-600 LPS)
Maximum Operating Pressure: Aluminum & Brass: 600 PSIG (40 Bar)

Stainless Steel: 1000 PSIG (69 Bar)

Maximum Operating Temperature: 240°F (116°C) Note: For operation to 600°F (316°C), see our High Temp datasheet.
Standard Calibration Fluids:Air @ 70°F (21°C), 1.0 sg and 100 PSIG (6.8 Bar)
Filtration Requirements: 74 micron filter or 200 mesh screen minimum
Materials of Construction (non-wetted components):

Window Tube:  Polycarbonate
Window Seals: 
Buna-N®

MATERIALS OF CONSTRUCTION (WETTED COMPONENTS):

Casing & End Ports: Anodized Aluminum, Brass, or Stainless Steel
Seals:

  • Aluminum: Buna-N® (STD),EPR, FKM, or FFKM
  • Brass: Buna-N® (STD),EPR, FKM, or FFKM
  • Stainless Steel: FKM with PTFE backup (STD), Buna-N®, EPR or FFKM

Transfer Magnet: PTFE coated Alnico
All other internal parts: Stainless steel

Reviews

There are no reviews yet.

Be the first to review “PNEUMATIC FLOW METER”

Your email address will not be published. Required fields are marked *