ACI Q5 B5 SERIES

Category:

ACI Q5 B5 SERIES SMART GAS TRANSMITTER  | BACnet & MODBUS GAS DETECTORS 

The ACI Q5/B5 Series consists of microprocessor-based smart gas transmitters designed to monitor and detect a wide variety of toxic and combustible gases in commercial and industrial environments. 

APPLICATIONS:

  • Mechanical Rooms
  • Warehouses
  • Refrigeration Plants
  • Industrial Plants
  • Process Monitoring
  • Leak Detection
  • Parking Garages
  • Auto/ Truck Maintenance Facilities
  • Oil and Gas Industry

 

ACI Q5 B5 SERIES SMART GAS TRANSMITTER  | BACnet & MODBUS GAS DETECTORS 

The Q5/B5 Series offers highly versatile gas detection solutions housed in durable, NEMA 4X rated plastic enclosures. The Q5 Series primarily provides analog outputs (4-20 mA, 1-5 VDC, or 2-10 VDC) and supports the proprietary RS-485 Modbus RTU/OptoMux protocol. The B5 Series is specifically designed for integration with Building Automation Systems (BAS), utilizing the BACnet MS/TP protocol. Both models feature an internal clock, a backlit LCD display for real-time concentration monitoring, and three user-configurable SPDT relays for direct control of auxiliary equipment like fans or alarms. Field-replaceable, pre-calibrated sensor modules simplify maintenance and minimize system downtime.

PRODUCT USES:

  • Parking Garages: Monitors Carbon Monoxide (CO) and Nitrogen Dioxide (NO2) to control ventilation fans.
  • Mechanical & Boiler Rooms: Detects leaks of combustible gases or toxic combustion byproducts.
  • Industrial Plants: Provides process monitoring and leak detection for hazardous gases like Ammonia (NH3), Chlorine (Cl2), and Hydrogen (H2).
  • Refrigeration Plants: Monitors for refrigerant gas leaks to ensure facility safety.
  • Warehouses & Maintenance Facilities: Ensures safe air quality in areas where gas-powered equipment is operated.

 

Specifications

TRANSMETTEUR DE GAZ INTELLIGENT SÉRIE ACI Q5 B5 | DÉTECTEURS DE GAZ BACnet ET MODBUS – SPÉCIFICATIONS CLÉS

Tension d’alimentation : 24 VDC ou 24 VAC nominal.

Protocoles de communication : Q5 (Modbus RTU, OptoMux) ; B5 (BACnet MS/TP).

Sorties analogiques (Q5 seulement) : 4-20 mA, 1-5 VDC ou 2-10 VDC.

Relais : Trois relais SPDT (forme C) à contacts secs ; 1,0 A @ 30 VDC ou 0,3 A @ 125 VAC.

Affichage : Écran LCD rétroéclairé affichant la TWA (moyenne pondérée dans le temps), le STEL (limite d’exposition à court terme) et la concentration actuelle.

Alarme sonore : Avertisseur intégré de 80 dB avec trois tonalités programmables.

Indice de protection du boîtier : NEMA 4, 4X, 12, 13 et IP66.

Température de fonctionnement : -40 °C à 70 °C (-40 °F à 158 °F), selon le type de capteur.